This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
nas-ups [2023/06/27 20:22] – [UPS Monitor] -condense, grammar hogwild | nas-ups [2024/11/27 18:00] (current) – [Daemon Log Entries] hogwild | ||
---|---|---|---|
Line 1: | Line 1: | ||
====== UPS Monitor ====== | ====== UPS Monitor ====== | ||
- | This menu is divided in two sections, the APC UPS Status table and APC UPS Response strings. UPS monitoring is only available for APC uninterruptible power supplies with USB connection compatible with APC’s smart protocol library. | + | The UPS Monitor |
- | For more details, see: [[https://networkupstools.org/protocols/apcsmart.html]] | + | Monitoring is available only for APC UPSes with a USB connection compatible with the APC smart protocol library. The UPS Monitor library is included only in the Mega-VPN and AIO// //builds. |
- | To establish a connection, first enable //USB 1.1 support (OHCI) //and// //enable the //Run APCUPSD Daemon// option | + | \\ |
+ | |||
+ | The menu is divided | ||
+ | |||
+ | | ||
+ | - APC UPS Response strings. | ||
\\ | \\ | ||
- | {{UPS_Monitoring_configuration.jpg?746}} | + | For more details, see: [[https:// |
+ | |||
+ | \\ | ||
+ | |||
+ | To establish a connection: | ||
+ | |||
+ | - In the USB Support menu, enable //USB 1.1 support (OHCI)// | ||
+ | - Enable the //Run APCUPSD Daemon// option. Click Save.\\ \\ \\ {{:: | ||
\\ | \\ | ||
Line 16: | Line 28: | ||
===== APC UPS Status ===== | ===== APC UPS Status ===== | ||
- | This section contains a table displaying the UPS model name, status, charge level, line voltage, load, and estimated run time. | + | {{: |
\\ | \\ | ||
- | {{:ups_monitoring_status.jpg? | + | Here, a table is displayed containing UPS: |
- | \\ | + | * Model name |
+ | * Status | ||
+ | * Charge level | ||
+ | * Line voltage | ||
+ | * Load | ||
+ | * Estimated run time.\\ | ||
\\ | \\ | ||
Line 29: | Line 46: | ||
===== APC UPS Response ===== | ===== APC UPS Response ===== | ||
- | This section contains | + | Here, a list of text strings |
\\ | \\ | ||
- | {{: | + | {{: |
\\ | \\ | ||
Line 39: | Line 56: | ||
\\ | \\ | ||
- | This contains the same information | + | This contains the same data as other tools (like apcupsd** **UPS control** **daemon on a Windows LAN device: |
\\ | \\ | ||
- | {{: | + | {{: |
\\ | \\ | ||
Line 54: | Line 71: | ||
==== Daemon Log Entries ==== | ==== Daemon Log Entries ==== | ||
- | A good way to debug issues with the UPS daemon is to check the Logs menu for entries | + | A good way to debug issues with the UPS daemon is to check the Logs for entries |
- | \\ For example, see the last entry shown on this Logs screen: | + | \\ For example, see the last entry on this screen: |
- | | + | \\ |
- | \\ \\ The last log entry shown here indicates that the apcupsd daemon started without problems. | + | {{:: |
- | \\ | + | |
- | \\ | + | |
+ | |||
+ | | ||